The air inlet panel on the indoor unit opens the closes easily, making filter cleaning simple. The suction panel can also de removed.
Enzymes used in the filter are naturally occurring lytics enzymes which attack cell walls of micro-organisms trapped on the filter and destroy them.
The blower fan has undergone anti-microbial to resist mold and germs, maiking the system clean and safe. Foul odors and molds, etc. Which can occur when an air conditioning system is not in operation are prevented.
The air conditioner automatically selects from heating, cooling or dry operation.
By combining a start timer with a stop timer you can register two timer operations a day. Once set timers will start or stop the system at the specified time of the day repeatedly.
The unit stops at the specified time.
This enables the operation to start a little earlier so that the room is near to set temperature at ON time.
By combining a start timer with a stop timer you can register two timer operations a day. Once set timers will start or stop the system at the specified time of the day repeatedly.
On the indoor unit there is a back up on/off switch. The system will operate in the previous mode.
Power blackout auto restart function records the operational status of the air conditioner immediately prior to being switched off by power supply interruption. The unit automatically resumes operations in that mode and temperature set point after the power has been restored.
With wireless “Luminous” remote controls that even “glow in the dark”, it is possible to operate all desired functions of the unit with the click of a button.
An inverter system has a number of advantages over a constant speed system. Its variable speed compressor outputscan ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner canslow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motordriven so it provides higher performance.
MODEL |
Indoor unit |
SRK25ZS-S |
SRK35ZS-S |
SRK50ZS-S |
||
ITEM |
Outdoor unit |
SRC25ZS-S |
SRC35ZS-S |
SRC50ZS-S |
||
Power source |
|
1 Phase, 220/240V, 50Hz |
||||
Capacity |
Cooling |
kW - Btu/h |
2.5(1.0~3.0) - 8,530(3,412~10,236) |
3.5(1.0~3.8) - 11,942(3,412~12,966) |
5.0(1.7~5.5) - 17,060(5,800~18,766) |
|
Heating |
kW - Btu/h |
3.2(0.9~4.4) - 10,918(3,071~15,013) |
4.0(0.9~4.8) - 13,348(3,071~16,378) |
5.8(1.6~6.6) - 19,790(5,459~22,519) |
||
Input |
Cooling |
kW |
0.62 |
1.01 |
1.56 |
|
Heating |
kW |
0.8 |
1 |
1.59 |
||
CSPF |
|
|
6.81 |
5.87 |
5.06 |
|
Current |
Cooling |
A |
3.2 / 3.1 / 3.0 |
4.9 / 4.7 / 4.5 |
7.2 / 6.9 / 6.6 |
|
|
Heating |
A |
4.0 / 3.8 / 3.6 |
4.9 / 4.7 / 4.5 |
7.3 / 7.0 / 6.7 |
|
Exterior dimension |
Indoor unit |
|
A |
290 x 870 x 230 |
||
(H x W x D) |
Outdoor unit |
|
A |
540 x 780(+62) x 290 |
540 x 780(+62) x 290 |
595 x 780(+62) x 290 |
Net Weight |
Indoor unit |
|
kg |
9.5 |
9.5 |
10 |
Outdoor unit |
|
kg |
31.5 |
34.5 |
36.5 |
|
Air Flow |
Indoor unit |
Cooling |
m3/min |
9.9 / 8.0 / 5.9 / 5.0 |
11.3 / 8.7 / 7.0 / 5.0 |
12.1 / 9.9 / 7.4 / 5.9 |
|
Heating |
m3/min |
11.3 / 8.7 / 6.7 / 5.9 |
12.3 / 11.0 / 7.0 / 5.6 |
13.9 / 11.2 / 9.1 / 7.4 |
|
Outdoor unit |
Cooling/Heating |
m3/min |
27.4 / 23.6 |
31.5 / 27.8 |
32.8 / 32.8 |
|
Refrigerant |
|
|
R410A |
|||
Refrigerant piping |
Liquid line |
|
mm |
ᶲ 6.35 (1/4”) |
ᶲ 6.35 (1/4”) |
|
Gas line |
|
mm |
ᶲ 9.52 (3/8”) |
ᶲ 12.7 (1/2”) |
||
Connecting wiring |
|
|
1.5mm2 x 4 cores (including earth cable) |
|||
Connect method |
|
|
|
Terminal Block ( Srew fixing type) |